  • Accurate high vacuum physisorption analyses of surface area and micropores
  • Advanced measurement routines made accessible with DoseWizard point selection and PowderProtect
  • Up to three samples, three gases, and three temperatures can be measured simultaneously with independent analysis stations
For Additional Information Request a Quote

Description

Autosorb instruments are high vacuum physisorption and chemisorption analyzers designed for advanced measurements of BET surface area, active area, and pore size distributions. Independent analysis stations, exclusive TruZone active coolant control, and accessible Kaomi software let you meet your current measurement needs, while factory and field upgradeable options let you adapt to future ones. For your most important gas sorption measurements, the choice is clear: Absolutely Autosorb.

Key features

A gas sorption analyzer that’s absolutely accurate

  • Get highly accurate physisorption measurements from relative pressures below 10-7 for nitrogen
  • Leverage precise manifold temperature control between 35 °C and 50 °C
  • Rely on TruZone active coolant level control for accurate data – even over lengthy analyses
  • Achieve superior high vacuum performance (38 % better than previous generation instruments) with precision-machined manifolds and high-quality pneumatic valves

Independent stations ensure you’re absolutely agile

  • Analyze up to three different samples with three different analysis gases at three different temperatures simultaneously with independent analysis stations and patented temperature control accessories
  • Perform the most challenging physisorption measurements with the 90-hour Dewar
  • Maximize your throughput with six integrated degassing stations
  • Quickly swap to the 1100 °C furnace for advanced temperature programmed analyses, pulse titrations, or chemisorption isotherms

Intuitive software makes every analysis absolutely accessible

  • Enjoy an updated and streamlined Kaomi software, which makes the whole measurement process easier than ever before
  • Optimize measurement definition to suit your needs with DoseWizard’s new standard and advanced modes
  • Keep downtime to a minimum with PowderProtect, which prevents accidental loss of powder in the instrument

Customization options keep you absolutely adaptable

  • With 3 instruments and modular upgrades, the Autosorb adapts to the exact analysis requirements of your porous solids and catalysts
  • As your research changes, the instrument’s physisorption and chemisorption features can be field upgraded to fit new materials and applications
  • Go beyond standard measurements with enhanced chemical resistance, a built-in vapor source, thermal conductivity detector, or even a fully integrated mass spectrometer

Compliance and quality are absolutely assured

  • Comply with 20+ ASTM, DIN, and ISO standards for catalyst characterization and the evaluation of porous solids.
  • Get peace of mind with our 3-year warranty so you can avoid unforeseen costs

Specifications

Measurement Specifications

Autosorb 6100 Autosorb 6200 Autosorb 6300
Measurement principle
  • Vacuum Volumetric Physisorption
  • Vacuum Volumetric Physisorption
  • Vacuum Volumetric Chemisorption
  • Dynamic Flow Chemisorption (Optional)
  • Vacuum Volumetric Physisorption
  • Vacuum Volumetric Chemisorption
  • Dynamic Flow Chemisorption
Analysis gas compatibility
N2, Ar, Kr, CO2, H2, and other non-corrosive gases Included Included Included
CH4, C2H6, C3H8, other alkanes, C6H6, C8H10 Included Dependent on instrument configuration Included
NH3, C5H5N, C3H6O, and other reactive gases N/A Dependent on instrument configuration Included
Physisorption analysis stations Number: 1, 2, or 3
Independence: Up to 3 gases at 3 analysis temperatures can be used concurrently,
1 analysis gas and temperature per station
Chemisorption analysis stations N/A 1
Independent p0 station Yes (dedicated cell and transducer)
Pressure
  • Range: 2×10-5 to 1100 Torr (2.6×10-8 to 0.997 p/p0 for N2 77K)
  • Resolution (MP): 2×10-5 Torr (2.6×10-8 p/p0 for N2 77K)
  • Resolution (XR): 1×10-6 Torr (1.3×10-9 p/p0 for N2 77K)
BET surface area
  • Absolute detection limit: 0.1 m2 (N2 77K)
  • Specific detection limit: 0.01 m2/g (N2 77K)
  • Typical reproducibility: 1 % (measured on BAM P115)
  • Reproducibility limit: 2 % with 2 m2 in the cell
Pore size
  • Range: 0.35 nm to 500 nm (diameter)
  • Typical reproducibility: 0.5 % (measured on BAM P115)
Active area N/A
  • Absolute detection limit: 0.03 m2 (H2 on Platinum 313 K)
  • Specific detection limit: 0.003 m2/g (H2 on Platinum 313K)
  • Typical reproducibility: 2 % (measured on 2% Platinum on Alumina reference sample)
TruZone Yes (active coolant level control)
PowderProtect Yes (prevents sample elutriation)
Analysis dewar
  • Duration: 90+ hours with liquid nitrogen
  • Refill during analysis: Yes
  • Volume: 3 L
Analysis furnace N/A
  • Maximum temperature: 1,100 °C
  • Maximum Ramp Rate: 50 °C per minute
  • Furnace cooling by built-in fan
Sample preparation
  • Integrated degassing stations: 6
  • Temperature control: 2 independent heating zones, ambient to 450 °C
  • Dedicated cold trap: Yes
  • Available methods: flow and vacuum, programmable multi-step degassing profiles, test for completion routines, pressure-controlled heating
Additional capabilities
Vapor source Optional Optional Included
CryoSync control  Optional Optional Optional
TCD and loop injector N/A Optional Included
Mass spectrometer N/A Optional Optional

Kaomi software features

Autosorb 6100 Autosorb 6200 Autosorb 6300
Instrument connection Control up to 4 instruments from 1 PC
DoseWizard
  • 45+ built-in analysis profiles aligned with ASTM, DIN, and ISO
  • Standard profiles with easy measurement selection
  • Advanced profiles with full control of experimental procedures
  • Dose templates for rapid measurement based on previous analyses
Physisorption methods
  • Surface area and pore volume: Alpha-s, BET, DR, Gurvich pore volume, Langmuir, t-plot (STSA)
  • Pore size and pore volume distributions: NLDFT, QSDFT, GCMC, Kr(87) thin-film, BJH, DH, DA, HK, SF, MP
  • Other: summary reports, overlays, average particle size, average pore size, fractal dimensions (NK, FHH), heat of adsorption
Chemisorption methods N/A
  • Static measurements: extrapolation, bracketing, Langmuir, Temkin, Freundlich, heat of adsorption
  • Dynamic flow measurements: TPx (TPR,TPO,TPD) peak deconvolution, pulse titration analysis, activation energy
Available languages Chinese, English, French, German, Japanese, Korean, Portuguese, Spanish

Technical Specifications

Autosorb 6100 Autosorb 6200 Autosorb 6300
Dimensions (W x D x H) 79.5 cm x 70.1 cm x 107.9 cm (31.3 in x 27.6 in x 42.5 in) dependent on instrument configuration
Weight 136.4 kg (300 lbs) dependent on instrument configuration
Operating environment
  • Temperature: 15 °C to 35 °C (59 °F to 95 °F)
  • Humidity: 20% RH to 80% RH, non-condensing
Gas distribution manifold elastomers FKM FKM or EPDM (dependent on instrument configuration) PFE
Analysis manifold construction Vacuum-brazed manifold block in stainless steel
Analysis manifold temperature
  • Range: user adjustable 35 °C to 50 °C
  • Stability: ±0.05 °C
Analysis manifold valves
  • Type: stainless steel, air-operated bellows valve
  • Cycle life: 5,000,000 cycles
  • External leak rate: 5×10-12 Pa m3/sec
  • Seat leak rate: 5×10-12 Pa m3/sec
Pressure transducer (1550 Torr) 
-Analysis and degas
  • Number: 3 to 5 (dependent on instrument configuration)
  • Accuracy: ±0.065% full scale* (*This value incorporates precision, linearity, and hysteresis for the entire pressure measurement system)
  • A/D data acquisition: 32 bit
Pressure transducer (10 Torr)
– MP or XR
  • Number: 1 to 3 (dependent on instrument configuration)
  • Accuracy: ±0.15 % reading up to 10 Torr
  • Resolution: 0.002 % full scale
Pressure transducer (1 Torr)
– MP only
  • Number: 1 to 3 (dependent on instrument configuration)
  • Accuracy: ±0.15 % reading up to 1 Torr
  • Resolution: 0.002 % full scale
Pressure transducer (0.1 Torr)
– XR only
  • Number: 1 to 3 (dependent on instrument configuration)
  • Accuracy: ±0.15 % reading up to 0.1 Torr
  • Resolution: 0.001 % full scale
Pirani vacuum gauge
– Degas only
  • Number: 1
  • Accuracy:
    5×10-4 to 1×10-3 Torr: ±10 % of reading
    1×10-3 to 100 Torr: ±5 % of reading
  • 100 Torr to atmosphere: ±25 % of reading
Vacuum system
  • Turbo molecular drag pump and dry diaphragm pump
  • Manufacturer’s specification: 5×10-10 mbar
  • Typical pressure at analysis port: 2.67×10-5 mbar
Thermal conductivity detector (TCD) N/A
  • Two-filament TCD with rhenium/tungsten filaments (optional)
  • Detection Limit: 0.5 uL (air injected into helium)
  • Two-filament TCD with rhenium/tungsten filaments (standard)
  • Detection Limit: 0.5 uL (air injected into helium)
Gas ports
  • 7 ports standard (5 analysis, 1 helium, 1 degas/backfill)
  • 7 additional analysis ports optional
  • 7 ports standard (5 analysis, 1 helium, 1 degas/backfill)
  • 7 additional analysis ports optional
  • 1 titration gas port optional
  • 15 ports standard (12 analysis, 1 helium, 1 degas/backfill, 1 titration)
Gas supply
  • Purity: 99.999 %
  • Input pressure: 8 psig to 10 psig (0.55 bar to 0.69 bar)
Air
  • Input pressure: 50 psig to 100 psig (3.45 bar to 6.9 bar)
Electrical
  • Supply: 100 to 240 VAC ±10%, 50 or 60Hz
  • Maximum consumption: 1600W (dependent on instrument configuration)
PC connection Ethernet
RoHS3 compliant Yes
CE / UKCA certified Yes